About Us

Latest Developments

:

Optimizing Static Gel Strength Testing Methods in Cementing Operations

The Static Gel Strength Tester, designed in strict adherence to API Standard Specification 10, plays a crucial role in simulating the harsh conditions of underground high temperature and high pressure environments. This sophisticated instrument is engineered to continuously measure changes in the strength of oil well cement, providing critical data for cementing operations in the oil and gas industry. Given its compact size and lightweight design, it is particularly well-suited for both laboratory and field testing, offering significant advantages in terms of portability and ease of use.

The Static Gel Strength Tester utilizes an advanced PLC+PC software system to manage its operations, which significantly enhances the testing process. This system allows users to set experimental parameters with precision through a user-friendly digital interface. The sophisticated software eliminates the need for manual adjustments, thus streamlining the testing process. By inputting parameters directly into the software, users can customize their tests more efficiently, reducing the potential for human error and improving overall accuracy.

The integration of PLC (Programmable Logic Controller) with PC-based software facilitates real-time monitoring and control of the testing environment. This means that users can oversee the testing process from a computer screen, where they can view experimental data and graphical curves in real time. The visual representation of data helps in immediate analysis and interpretation, making the testing more intuitive and less prone to mistakes.

Furthermore, the software enables users to save and output data with ease. Screenshots of data and results can be captured and stored for future reference or reporting purposes, ensuring that all relevant information is documented comprehensively. This feature not only aids in maintaining accurate records but also supports thorough analysis by providing clear, organized data presentation.

The Static Gel Strength Tester is designed to deliver precise and dependable results through the integration of advanced safety and performance features. To maintain the integrity of the testing process, the instrument incorporates a series of alarms that monitor critical parameters such as temperature and pressure. These alarms are crucial for early detection of any deviations from the set conditions, allowing users to address potential issues before they escalate. For instance, if the temperature or pressure deviates from the predefined range, the alarm system promptly alerts the operator, enabling immediate corrective action. This proactive approach significantly reduces the risk of erroneous results and ensures that the test conditions remain stable throughout the experiment.

In addition to these alarm systems, the Static Gel Strength Tester is equipped with a safety feature that allows the entire system to be deactivated with a single click. This feature enhances operational safety by providing a quick and straightforward method for stopping the test in case of emergencies or other urgent situations. The ease with which the system can be shut down not only improves the safety of the testing environment but also minimizes potential damage to the equipment or samples.

The construction of the Static Gel Strength Tester reflects a commitment to high standards of durability and performance. The instrument incorporates top-tier components such as the Siemens PLC, which serves as the central control unit for the testing operations. Siemens PLCs are renowned for their reliability and precision, making them an ideal choice for managing the complex controls required by the tester. Complementing the PLC is the HIP valve, known for its robustness and ability to handle high pressures, ensuring the tester operates smoothly under various conditions.

The Eurotherm thermostat included in the instrument further enhances its performance by providing precise temperature control. Eurotherm products are celebrated for their accuracy and stability, making them essential for maintaining the exact temperature required during testing. Additionally, the tester features Japanese-customized thermocouples, which are tailored to meet the specific needs of the instrument. These thermocouples offer exceptional accuracy and durability, contributing to the overall reliability of temperature measurements.

Together, these high-quality components ensure that the Static Gel Strength Tester operates with both durability and precision. The advanced safety features and top-tier construction elements collectively contribute to a testing instrument that not only meets but exceeds industry standards for reliability and performance.

Setting up and calibrating the Static Gel Strength Tester involves a series of critical steps to ensure accurate and reliable operation. The process begins with establishing the essential connections for the instrument. Initially, users need to connect the water inlet and outlet lines, as well as the coolant connections, which are crucial for maintaining the appropriate temperature conditions during testing. These connections must be securely fitted to prevent leaks and ensure the proper flow of fluids.

Once the fluid connections are in place, the next step involves connecting the Static Gel Strength Tester to a computer. This is achieved through both network and USB ports, which enable communication between the instrument and the computer. Proper connection to the computer is essential for controlling the tester and accessing its data through the accompanying software.

After connecting the device, users should power it on and launch the software. The software serves as the interface for configuring the instrument and conducting tests. A critical step in this phase is verifying the communication link between the tester and the computer. This ensures that data transmission is functioning correctly and that the software can accurately control and monitor the tester. Verification involves checking that the software detects the instrument and that all system diagnostics are reporting normal operations.

By carefully following these setup and calibration steps, users ensure that the Static Gel Strength Tester is correctly prepared for precise and effective testing, thereby achieving reliable results.

Next, attention must be given to the slurry cup's sealing ring and the U-shaped pipe connecting to the cup. The sealing ring should be inspected and replaced if it shows signs of aging or damage, while the U-shaped tube must be free of blockages. Proper installation is crucial, as the metal sealing ring should not be placed incorrectly. Applying a thin layer of high-temperature grease to the inner walls, threads of the cup, and sealing rings helps facilitate easier cleaning and ensures a good seal.

The bottom cap of the slurry cup is then installed at the lower end, tightened manually, and slightly loosened for easier removal later. A thin layer of coupling agent is applied to the transducers' front ends, which are then connected to the upper and lower caps. After securing the cup and lower cover on the bench clamp, and preparing the slurry, the cement slurry is poured into the cup. It is essential to maintain the slurry level between the specified upper and lower limits to avoid contamination of other parts of the cup.

Once the slurry is in place, a small amount of water is added to reach the water level mark on the ruler. The top cap is then manually screwed onto the cup, ensuring that any excess water flows out, indicating the absence of air in the cup. The top cap is tightened manually and then slightly loosened for easier disassembly.

Preparing the Static Gel Strength Tester for an experiment involves a meticulous series of steps to ensure proper setup and calibration. Initially, the outside wall of the slurry cup must be cleaned thoroughly before it is placed into the heating mantle. This cleaning is essential to prevent any contaminants from affecting the test results. Additionally, care must be taken to avoid severe bending of the wire that passes through the mantles bottom hole during this process. Any damage to this wire could impact the instruments functionality and lead to inaccurate measurements.

Once the slurry cup is clean, it is positioned into the heating mantle. The cup should be aligned carefully to ensure that the pressure hole on the top cap is correctly positioned relative to the U-shaped pipe's thread. This alignment is crucial because it ensures that the pressure measurements will be accurate and that the testing system will operate correctly.

After placing the cup, the next step is to secure the U-shaped pipe. The nuts at both ends of the U-shaped pipe are first tightened by hand. This preliminary tightening helps to ensure that the pipe is aligned correctly before applying more force. Following this, a wrench is used to tighten the nuts securely. Proper tightening of these nuts is important to prevent any leaks or misalignment during the testing process.

The thermocouple, which is critical for measuring temperature, is then inserted into the hole in the top cap of the slurry cup. The corresponding wires from the thermocouple are connected to the instrument, establishing a necessary link for accurate temperature readings. Ensuring that these connections are secure is crucial for the reliability of temperature data.

Once the connections are made, the pump water supply switch is turned on. It is important to verify that water flows out from the thermocouple connection. This indicates that the system is properly primed and that there are no blockages or leaks. After confirming the water flow, the nut at the thermocouple connection is tightened with a wrench to ensure a secure seal. Any excess water that might have accumulated is then wiped away to prevent interference with the testing equipment.

With the setup complete, experimental parameters such as pressure and temperature need to be configured in the software. The software interface allows for precise control over these parameters, ensuring that the test conditions are set according to the requirements. After setting the parameters, the pump switch is activated to pressurize the cement, and the heating switch is turned on to begin the heating process. With all switches engagedthe pump switch, water supply switch, and heating switchthe softwares 'Start' button is clicked to initiate the experiment. This comprehensive setup ensures that the Static Gel Strength Tester is ready to conduct accurate and reliable testing.

In conclusion, optimizing the static gel strength testing methods in cementing operations involves meticulous setup, careful calibration, and precise control of experimental conditions. By leveraging advanced technologies and adhering to stringent procedures, the Static Gel Strength Tester ensures reliable measurement of cement strength under simulated high-temperature and high-pressure conditions, thus playing a vital role in the success of cementing operations in the oil and gas industry.